BVGLK - FLUX-OFF C1690, C2490
- MSDS: BVGLK
- Manufacturer: CHEMTRONICS INC
- Product Name: FLUX-OFF C1690, C2490
- National Stock Number: 6850-00-419-5004
Product Identification
Product ID:FLUX-OFF C1690, C2490
MSDS Date:10/01/1992
FSC:6850
NIIN:00-419-5004
MSDS Number: BVGLK
Responsible Party
KENNESAW, GA 30144
US
Emergency Phone: 770-424-4888/800-424-9300(CHEMTRAK)
Info Phone: 800-645-5244 FAX 770-424-4267
Preparer: M. WATKINS
Cage: 2M589
Contractor
Telephone: 770-424-4888/800-645-5244
Cage: 2M589
Ingredients
1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA
CAS: 76-13-1
RTECS: KJ4000000
Fraction By Weight: 42-43%
OSHA PEL 1000PPM
ACGIH TLV: 1000PPM/1250STEL9394
METHYLENE CHLORIDE (DICHLOROMETHANE) (SARA III)
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 42-43%
OSHA PEL 500 PPM; Z-2
ACGIH TLV: 50 PPM, A2; 9394
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
OSHA PEL 5000 PPM
ACGIH TLV: 5000PPM/30000STEL;94
CHLORODIFLUOROMETHANE
CAS: 75-45-6
RTECS: PA6390000
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM; 9394
Hazards
LD50 LC50 Mixture:LD50 (RAT)= 5000 MG/KG; SEE SUPP. SECT.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION MAY CAUSE
ASPHYXIATION. LIQUID CONTACT MAY CAUSE SKIN AND EYE IRRITATION.
SKIN ABSORPTION MAY BE HARMFUL. INGESTION MAY CAUSE GI TRACT
IRRITATION. CHRONIC: NONE SPECIFIED BY MANUFACT URER.
Explanation of Carcinogenicity:METHYLENE CHLORIDE IS LISTED BY NTP AND
IARC (PER MANUFACTURER-NOT FOUND BY DLA-HMIS).
Effects of Overexposure:INHALED-LIGHT HEADEDNESS, GIDDINESS, SHORTNESS
OF BREATH, POSSIBLE NARCOSIS, POSSIBLE CARDIAC ARRYTHMIAS AT HIGH
CONCENTRATIONS, HEADACHE, CIRCULATORY SYSTEM DEPRESSION,
UNCONSCIOUSNESS, DEATH. SKIN-R EDNESS, DRY SKIN, DISCOMFORT.
INGESTED-NAUSEA, VOMITING. EYES-REDNESS, TEARING, DISCOMFORT.
Medical Cond Aggravated by Exposure:CARDIOVASCULAR DISEASE AND SKIN
DISEASE.
First Aid
First Aid:GET MEDICAL ATTENTION. EYES-FLOOD WITH WATER FOR 15
MINUTES.SKIN-FLUSH WITH WATER FOR 15 MINUTES.INHALED-MOVE TO FRESH
AIR.IF BREATHING DIFFICULT,GIVE OXYGEN.IF BREATHING STOPPED,GIVE
ARTIFICIAL RESPI RATION.INGESTED-DO NOT INDUCE VOMITING.IF
CONSCIOUS,GIVE 1-2 GLASSES OF WATER OR ACTIVATED CHARCOAL SLURRY.
DOCTOR'S NOTE: DO NOT GIVE EPINEPHRINE BECAUSE OF INCREASED RISK OR
CARDIAC ARRHYTHMIAS.
Fire Fighting
Flash Point Method:TOC
Flash Point:NONE
Extinguishing Media:NONFLAMMABLE. DLA-HMIS: USE APPROPRIATE
EXTINQUISHING MEDIA FOR SURROUNDING FIRE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:PRESSURIZED AEROSOL CONTAINERS AT
ELEVATED TEMPERATURES MAY VENT, RUPTURE OR BURST AND ADD TO FLYING
AND FALLING DEBRIS. DECOMPOSITION MAY OCCUR.
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE OPEN FLAMES OR OTHER
SOURCES OF IGNITION. COLLECT SPILLED PRODUCT WITH ABSORBENT
MATERIAL & PLACE IN CLOSED STEEL DRUMS FOR PROPER DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE NEAR SOURCES OF HEAT, IN
DIRECT SUNLIGHT, OR WHERE TEMPERATIRES EXCEED 120F. DO NOT PUNCTURE
OR DAMAGE CONTAINERS. ROTATE STOCK.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NONE NORMALLY REQUIRED. IF ENGINEERING CONTROLS
FAIL OR NON-ROUTINE USE OR EMERGENCY OCCURS; USE NIOSH/MSHA
APPROVED RESPIRATOR OR SUPPLIED AIR RESPIRATOR OR SCBA, AS
REQUIRED. USE IAW 29 CFR 1910.134 AND MANUFACTURER'S
RECOMMENDATIONS.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION TO MAINTAIN EXPOSURE
BELOW TLV.
Protective Gloves:RUBBER
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHES AND EYE WASH STATION &
SAFETY SHOWER.
Work Hygienic Practices:WASH THROUGHLY AFTER HANDLING AND BEFORE
EATING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
LD 50 RATS= 43000 MG/KG FOR TRICHLOROTRIFLUOROETHANE, 5000 MG/KG FOR
METHYLENE CHLORIDE. THE LD 50 FOR METHYLENE CHLORIDE WAS USED IN
THE SPACE FOR LD50-LC50-MIXTURE SINCE THERE WAS NO DATA FOR THE MI
XTURE.
Chemical Properties
HCC:V2
Boiling Pt:=36.5C, 97.6F
Vapor Pres:500 MM HG
Vapor Density:2.7
Spec Gravity:1.42
Evaporation Rate & Reference:<1 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR, COLORLESS LIQUID WITH STRONG SOLVENT ODOR
Stability
Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS, POWDERED AL, ZN, BE, ETC.
Stability Condition to Avoid:AVOID SPRAYING NEAR OPEN FLAMES OR RED HOT
SURFACES. DO NOT HEAT CONTAINERS ABOVE 120F/49C.
Hazardous Decomposition Products:HYDROCHLORIC AND HYDROFLOURIC ACIDS,
POSSIBLE CARBONYL HALIDE.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL LOCAL,STATE &
FEDERAL REGULATIONS.DO NOT PUNCTURE OR INCINERATE AEROSOL CANS.SARA
311 QUANTITY:2000 LB.SARA 313(EPCRA,40 CFR
372):TRICHLOROTRIFLUORETHANE,42-43%,CAS#76-1 3-1;METHYLENE
CHLORIDE,42-43%,CAS#75-09-2.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.